Stannate and permanganate conversion coatings on AZ31 magnesium alloy |
| |
Authors: | F Zucchi A Frignani V Grassi G Trabanelli C Monticelli |
| |
Affiliation: | aCorrosion Study Centre “A. Daccó”, Chemistry Department, University of Ferrara, 46 L. Borsari, 44100 Ferrara, Italy |
| |
Abstract: | The formation of stannate and permanganate–phosphate conversion coatings on AZ31 magnesium alloy was investigated in situ by EIS measurements and their protective performances were studied by different electrochemical techniques in diluted (0.05 M) sodium sulphate solution.The influence that short or long treatment times exert on the performances of such conversion coatings is discussed. While permanganate–phosphate baths always built layers characterized by penetrating cracks, long stannate baths produced layers without interconnected porosity, but were defective. This accounted for the initial greater protectiveness achieved with the stannate treatment; nevertheless, the easy penetration of the electrolytic solution through such a layer quickly decreased its corrosion resistance. |
| |
Keywords: | A Magnesium alloy B EIS B Polarization curve C Conversion coating C Corrosion resistance |
本文献已被 ScienceDirect 等数据库收录! |