摘    要: 通过分析脉冲喷射开关阀的工作性能,提出致动器是决定脉冲喷射开关阀特性的关键因素.对比3种致动器的性能参数,指出GMA更适合脉冲喷射开关阀的工作要求.GMA的性能分析和仿真结果给出了在脉冲喷射开关阀中工作的GMA的静、动态特性.脉冲喷射开关阀单脉冲流量实验曲线表明:脉冲喷射开关阀的单脉冲流量随励磁电流的变化规律与GMA的磁致伸缩曲线特性相似,在GMA的磁致伸缩曲线的线性区即可满足单脉冲喷射流量要求.动态实验中,脉冲喷射开关阀的阀芯位移阶跃响应上升时间只有0.81 ms,远远满足脉冲喷射开关阀应用的工作频率要求.

关 键 词:GMA  脉冲喷射开关阀  超磁致伸缩  致动器
文章编号:1006-754X(2008)02-0109-05
修稿时间:2007年7月9日

Application of GMA in pulsed jet on-off valve
MENG Ai-hua,ZHOU Jian-jun,PAN Yu-liang,XIANG Zhan-qin.Application of GMA in pulsed jet on-off valve[J].Journal of Engineering Design,2008,15(2):109-113.
Authors:MENG Ai-hua  ZHOU Jian-jun  PAN Yu-liang  XIANG Zhan-qin
Affiliation:1.College of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China;
2.Institute of Modern Manufacturing Engineering, Zhejiang University, Hangzhou 310027, China
Abstract:Through analysis on working performance on pulsed jet on-off valve (PJOV), the conclusion that actuator is the key factor to determine the performance of such valve is drawn. By comparing the performance parameters of three actuators, it was concluded that GMA was the most suitable one for PJOV. Performance analysis and simulation result provided the static and dynamic properties of GMA in PJOV. Pulse flux experimental curve of PJOV indicates that changing rules of single-pulse flux with exciting currency is similar to curve property of magnetostriction of GMA, and the linear area of magnetostriction of GMA can fulfill the requirements of single-pulse jet flux. In dynamic experiments, the rising time of step response of valve stem was only 0.81 ms, which well fulfilled the requirements of PJOV.
Keywords:GMA  pulsed jet on-off valve  giant magnetostriction  actuator
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《工程设计学报》浏览原始摘要信息
点击此处可从《工程设计学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号