Push-out tests on a new shear connector of I-shape |
| |
Authors: | Aida Mazoz Abdelkader Benanane Messaoud Titoum |
| |
Affiliation: | 1. Laboratory of Materials and Processes of Construction, University of Mostaganem, Mostaganem, Algeria 2. Laboratory of Materials and Mechanics of Structures, University of M’sila, M’sila, Algeria
|
| |
Abstract: | In steel-concrete composite beams, the shear connectors are commonly used to transfer the longitudinal shear forces across the steel-concrete interface. This paper summarizes the results of 24 push-out test specimens with a new type of shear connector called “I-shape connector”. The test specimens were designed to study the effect of the following parameters on the ultimate load capacity: the height of I-shape connector, the length of I-shape connector, the compressive strength of concrete and the number of transverse reinforcing bars. The experimental results are presented and discussed, focusing on the failure modes and load-slip behaviour. Finally, the experimental results are compared to the existing design equations to predict the ultimate load capacity of I-shape shear connectors. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|