首页 | 本学科首页   官方微博 | 高级检索  
     


Specific determination of bromate in bread by ion chromatography with ICP-MS
Authors:Akiyama Takumi  Yamanaka Michiko  Date Yukiko  Kubota Hiroki  Nagaoka Megumi Hamano  Kawasaki Yoko  Yamazaki Takeshi  Yomota Chikako  Maitani Tamio
Affiliation:National Institute of Health Sciences: 1-18-1, Kamiyoga, Setagaya-ku, Tokyo 158-8501, Japan.
Abstract:A sensitive method for detecting bromate in bread by ion chromatography with inductively-coupled plasma mass spectrometry (IC/ICP-MS) was developed. Bromate was extracted from bread with water. The clean-up procedure included a 0.2 micron filter, a C18 cartridge for defatting, a silver cartridge to remove halogen anions, a centrifugal ultrafiltration unit to remove proteins, and a cation-exchange cartridge to remove silver ions. A 500 microL sample solution was applied to IC/ICP-MS. The detection limit and the quantitation limit of bromate in the solution were 0.3 ng/mL and 1.0 ng/mL, expressed as HBrO3, respectively, which corresponded to 2 ng/g and 5 ng/g, respectively, in bread. Recovery of bromate was about 90%, and the CV was about 2%. Based on the detection limit in solution and recovery from bread, the detection limit of bromate in bread was estimated to be 2 ng/g.
Keywords:
本文献已被 PubMed 等数据库收录!