摘    要:针对国产200MW汽轮机组液压式调速系统投产多年来经常发生卡涩、甩负荷不稳定运行的客观问题,对华能淮阴电厂2台200MW汽轮机调速系统进行了综合治理和技术攻关取得了成功的经验,值得国产同类型机组借鉴。

关 键 词:汽轮机  调速系统  故障分析
修稿时间:1999-01-20

Testing-analysis and Handling Experience of Governing System Fault of Indigenous 200MW Steam Turbine
Bu Shunli. Testing-analysis and Handling Experience of Governing System Fault of Indigenous 200MW Steam Turbine[J]. Electric Power, 1999, 32(5): 18-20
Authors:Bu Shunli
Abstract:Retarding and unstable operation problems during load rejection often occurred on the hydraulic control system of indigenous 200 MW steam turbines since they were put into operation.Through comprehensive tackling and technical retrofitting on the governing systems of two 200 MW steam turbines in Huaneng Huaiying Power Plant,these problems have been successfully solved with good results gained,worthing being used as reference for the same type indigenous steam turbines.