摘    要:建立了一套实用的臭氧分析方法,即用靛蓝滴定法测定高浓度臭氧,确定了吸收液使用25 mL的0.001 mol/L靛蓝溶液,并用磷酸盐缓冲溶液调节pH至6.8,温度控制在20℃,空气流量为200 mL/min,可以测定高达10 mg/L的臭氧.

关 键 词:靛蓝法  高浓度  臭氧

Study on Determination of High Concentration Ozone With Indigo Method
SHI Chun-wei,YAN Yu-ding,SONG Guan-long. Study on Determination of High Concentration Ozone With Indigo Method[J]. Contemporary Chemical Industry, 2011, 40(3): 326-328
Authors:SHI Chun-wei  YAN Yu-ding  SONG Guan-long
Affiliation:SHI Chun-wei,YAN Yu-ling,SONG Guan-long(Liaoning Shihua University,Liaoning Fushun 113001,China)
Abstract:A new method,indigo method was designed to determine high concentration ozone.The experiment conditions were confirmed as follows:using 25 mL indigo solution of 0.001 mol/L as absorption liquid,pH = 6.8 and temperature 20 ℃,air rate 200 mL/ min.The highest concentration of ozone that can be determined reaches to 10 mg/L.
Keywords:Indigo method  High concentration  Ozone  