摘    要:通过对LDJ/151型电除尘器检修与改造,使其基本达到设计参数的实例,介绍了提高电除尘器除尘效率的方法,可为相同型式的电除尘器检修及改进提供参考。

关 键 词:电除尘器  检修改造  提高效率

Measures to Raise the Electrostatic-Precipitating Efficiency of 200 MW unit
Zhao Qingbo. Measures to Raise the Electrostatic-Precipitating Efficiency of 200 MW unit[J]. Jilin Electric Power, 1997, 0(5)
Authors:Zhao Qingbo
Affiliation:Zhao Qingbo
Abstract:The method of raising electrostatic precipitation efficiency is recomended by describing by an example of overhauling and modifying a LDJ/151 Type Electrostatic Precipitator to reach its design parameters. It may be referred to overhauling and modifying the same type electrostatic precipitators.
Keywords:ELectrostatic Precipitator Overhaul and Modification Raise the Efficiency