Use of the higher spectra in the low-amplitude fatigue testing |
| |
Authors: | Marcin Jasinski Stanislaw Radkowski |
| |
Affiliation: | Institute of Automotive Engineering, Warsaw University of Technology, Narbutta 84, 02-524 Warsaw, Poland |
| |
Abstract: | Particular place among the methods of vibroacoustic diagnostics is occupied by the problems of early defect detection. Let us note that the process of defect formation may lead to both. The intensification of non-linear phenomena as well as the occurrence of non-stationary effects even if during the early stages the intensity of defects is small while the growth of the level of vibration and noise is negligible, as contrasted with emergency states. A useful method is to test the higher order spectra, which, respectively, define the non-linear effects. A test bed for low-amplitude tests (106-107 cycles) of fatigue processes was built. The authors built a small-dimension test bed for diagnosing the low-amplitude fatigue processes. Small dimensions result from the proposal of mounting the test bed on shaker. The dimensions of test bed are 0.2×0.2×0.2 m and its weight does not exceed 2 kg, with a titan head mounted directly on the piezoelectric generator. The main goal of these investigations is to examine the low-amplitude fatigue strength of a model of the cantilever supported section of a shaft and impact of dynamic stress, which is especially important in the case of high frequency loading which is predominant in mounting elements of rotating machinery. |
| |
Keywords: | Low-amplitude fatigue testing Higher-order spectra |