首页 | 本学科首页   官方微博 | 高级检索  
     


DC operation analysis of induction coil fluxmeters with integrating amplifiers
Authors:Martin Dadić
Affiliation:University of Zagreb, Faculty of Electrical Engineering and Computing, Unska 3, 10000 Zagreb, Croatia
Abstract:Modern fluxmeter operation is based on electronic integration. A system consisting of an induction coil and an integrator can be used to measure incremental changes in the flux linkages associated with the induction coil. A rigorous proof is presented that the inductance and self-capacitance of the induction coil, as well as the parasitics of the load resistor, do not influence the integrator output in measurement of incremental flux linkages using DC operation of the fluxmeter. The theoretical analysis is confirmed by experimental results.
Keywords:Fluxmeters   Integrating amplifiers   Induction coils   Coil capacitance   Coil inductance