摘    要:对酸洗过程还原Fe^3 的还原剂进行了筛选,讨论了Fe^3 浓度对腐蚀速率以及几种还原剂的加入对腐蚀速率的影响,并对实验结果进行对比,选出一种适合于锅炉化学清洗过程中还原Fe^3 的还原剂。结果表明,JF-206的加入可将Fe^3 ,且不增加腐蚀速率。

关 键 词:锅炉 化学清洗 还原剂 铁离子 去除 腐蚀速率
文章编号:1001-1560(2003)02-0042-02

Reductant of Fe3+ in Chemical Cleaning of Boiler
CHEN Bu-rong,ZHOU Yong-zhang,DING Yi. Reductant of Fe3+ in Chemical Cleaning of Boiler[J]. Journal of Materials Protection, 2003, 36(2): 42-43
Authors:CHEN Bu-rong  ZHOU Yong-zhang  DING Yi
Abstract:The reductants of Fe 3+ in pickling of boiler were screened, and the effects of Fe 3+ and several reductants on the corrosion rate were discussed. The reductant named JF-206 was a good additive, which could reduce the Fe 3+ to Fe 2+ entirely and did not increase the corrosion rate.