Heat transfer in three-phase fluidized beds |
| |
Authors: | C.G.J. Baker E.R. Armstrong M.A. Bergougnou |
| |
Affiliation: | Faculty of Engineering Science, University of Western Ontario, London, Ont. Canada |
| |
Abstract: | Heat transfer coefficients h have been measured in two-phase (water—air, water—glass beads) and three-phase (water—air—glass beads) fluidized beds. Experiments were performed over a wide range of liquid and gas flowrates in a 0.24 m diam. column fitted with an axially mounted cylindrical heater. Four solids were employed ranging in size from 0.5 to 5 mm.Typical maximum values of h in the three-phase, liquid—gas, liquid—solid and liquid beds were approximately 4800, 4300, 3800 and 1300 W/m2K respectively. In the three-phase beds h generally increased with liquid and gas velocity and with particle size. Correlations are presented to calculate h in the different beds. |
| |