首页 | 本学科首页   官方微博 | 高级检索  
     


Optimal design of cathode flow channel for air-cooled PEMFC with open cathode
Affiliation:1. Department of Mechanical Engineering, Inha University, 100 Inha-ro, Michuhol-gu, Incheon 22212, Republic of Korea;2. George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0405, USA;3. School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0245, USA;4. Center for Hydrogen & Fuel Cell Research, Korea Institute of Science and Technology, 14-gil 5 Hwarang-ro, Seongbuk-gu, Seoul 02792, Republic of Korea;1. Department of Energy Technology, Aalborg University, Pontoppidanstræde 101, DK-9220 Aalborg East, Denmark;2. Department of Mechanical Engineering, University of Louisville, KY 40292, USA;3. CSIR – Central Electrochemical Research Institute – Chennai Unit, CSIR Madras Complex, Taramani, Chennai 600-113, India;4. Wellness Convergence Research Center, DGIST, 50-1 Sang-Ri, Hyeongpung-Myeon, Dalseong-Gun, Daegu 711-873, Republic of Korea;1. School of Mechatronic Systems Engineering, Simon Fraser University, 250-13450 102 Avenue, Surrey, BC, V3T 0A3, Canada;2. Alternative Energy Department, Indian Oil R&D Centre, Sector-13, Faridabad, 121002, India
Abstract:Air-cooled open-cathode low temperature proton exchange membrane fuel cell (AO-LTPEMFC) with low weight, small volume and compact system has become the new potential power source in the unmanned aerial vehicle (UAV). However, the desirable parameters of the cathode channel are a very important factor to influence the cell performance and the compact of the stack, which have the higher requirements put forward to the structural designs of the cathode channel of AO-LTPEMFC. Thus, some single AO-LTPEMFC fabricated with different width:0.9–1.5 mm, depth:1.1–1.5 mm, ratio (width/landing):1:0.7–1:1.3 and bending:0–10° of the cathode channel was investigated to optimize the cell performance and temperature distribution in the 2 mm plate and determine desirable design parameters. The results show that the different design parameters of the cathode channel affect the contact resistance, oxygen mass transfer of cathode and pressure drop in air flow. For AO-LTPEMFC, to keep the best performance, the cathode channel design parameters should be operated at appropriate width, as deep as possible, small ratio and bending. Through the comparison of various designs, combined with practice process, the optimum design size with width (1.1 mm) × depth (1.3 mm) × width/landing (1:0.7) × bending angel (θ) (5°) was obtained based on the 2 mm thickness of the bipolar plate, which could get the maximum performance and improve the compactness of system. Moreover, analysis in this study will provide a new guideline for the development of cathode flow field plate design in application.
Keywords:AO-LTPEMFC  Cathode  Bipolar plate  Bending  Ratio  Performance
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号