Experimental study on performance of membrane humidifiers with different configurations and operating conditions for PEM fuel cells |
| |
Affiliation: | 1. Department of Mechanical Engineering, Faculty of Shahid Mohajer, Technical and Vocational University (TVU), Esfahan, Iran;2. School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran;3. Department of Mechanical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran;4. Institute of Materials and Energy, Isfahan, Iran |
| |
Abstract: | In this study on humidifiers for polymer electrolyte membrane (PEM) fuel cell application, the experimental outcome of two air-to-air planar membrane humidifiers with three different internal flow patterns including cross, parallel and counter flows are investigated under isothermal and insulated boundary conditions. At all temperatures and flow rates, the conditions of higher performance, corresponding to highest water recovery ratio (WRR) and lowest dew point approach temperatures (DPAT), are encountered in the counter flow case, in contrary to the cross flow configuration. The insulation condition with dry inlet temperature at 30 °C and wet inlet temperature at 60 °C has a higher WRR index compared to isothermal condition at 60 °C but is lower than isothermal condition at 30 °C. The DPAT in humidifier with insulation condition is approximately equal to that obtained in isothermal condition at 60 °C but is much higher than what results in isothermal condition at 30 °C. It can be deduced that the temperature of the wet side inlet plays a key role in the humidifier performance. |
| |
Keywords: | Membrane humidifier PEM fuel cell Insulation Isothermal Flow configuration |
本文献已被 ScienceDirect 等数据库收录! |
|