首页 | 本学科首页   官方微博 | 高级检索  
     


X-ray computed tomography of a gas-sparged stirred-tank reactor
Authors:Jason J Ford  Terrence C Jensen
Affiliation:a Department of Mechanical Engineering, Iowa State University, Ames, IA 50011-2161, USA
b Center for Nondestructive Evaluation, Iowa State University, Ames, IA 50011-2161, USA
Abstract:X-ray computed tomography (CT) is used to explore the differences in gas dispersion in a stirred-tank reactor (STR) for different operating conditions by varying the impeller speed and gas flow rate. X-ray imaging has been carried out in a 0.21 m ID acrylic STR equipped with a nylon Rushton-type impeller. From the CT images, major differences in local gas holdup are observed for different operating conditions. Completely dispersed conditions have a relatively uniform holdup profile while flooded conditions show a high gas holdup near the impeller shaft. The high resolution of the X-ray system allowed fine details such as recirculation regions behind the baffles to be visualized.
Keywords:Hydrodynamics  Multiphase flow  Stirred-tank reactor  Tomography  Visualization  Voidage
本文献已被 ScienceDirect 等数据库收录!