摘    要:提出了利用直读光谱仪分析钢中稀土元素的分析方法。验证了用轻稀代表稀土总量的实用性,确定了可行性的制样条件,校正共存元素的干扰,分析偏差小于GB/T223.49-94的再现性限,分析周期小于8min。

关 键 词:测定 钢 稀土 直读光谱

A DIRECT- READING SPECTROGRAPHIC DETERMINATION OF TOTAL AMOUNT OF RARE EARTH IN STEEL
Guo Fang Liu Xiang Shen Ke Qi Yu Cai Yingxin Liang Jianwei. A DIRECT- READING SPECTROGRAPHIC DETERMINATION OF TOTAL AMOUNT OF RARE EARTH IN STEEL[J]. Wisco Technology, 2002, 40(4): 21-24
Authors:Guo Fang Liu Xiang Shen Ke Qi Yu Cai Yingxin Liang Jianwei
Affiliation:Quality Inspection Center of WISCO Wuhan Hubei 430083
Abstract:The analytical method for determinatin of the total rare earth in steel using a direct-reading spectrograph is described;the validity of representation of the total amount of the rare earth in steel by the light rare earth verified;the effective preparation conditions determined;and the interference of the coexisting elements checked.Results show that the analytical error is controlled within the reproduction limit of GB/T223.49-94 and the analytical cycle is less than 8 minutes.