摘    要:针对一台燃气工业锅炉出现的低温级过热器爆管问题,从设计、过热器结构、布置等诸方面分析了引起爆管的原因,并提出了解决爆管的措施。

关 键 词:40t/h燃气锅炉  过热器  爆管  锅炉运行  安全
文章编号:1001-2060(2002)06-0644-03

An Analysis of the Cause of a Superheater Tube Explosion Occurring in a 40 t/h Gas-fired Boiler
FAN Wei dong,ZHANG Ming chuan.An Analysis of the Cause of a Superheater Tube Explosion Occurring in a 40 t/h Gas-fired Boiler[J].Journal of Engineering for Thermal Energy and Power,2002,17(6):644-647.
Authors:FAN Wei dong  ZHANG Ming chuan
Abstract:The tube explosion occurring in a low temperature stage superheater of a gas fired industrial boiler was analyzed from various aspects, such as boiler design, superheater structure and layout, etc. With the cause of explosion being identified some effective measures were proposed to solve the problem.