摘    要:汽轮机超速事故是对电厂中发电设备破坏性最大的事故,所以发电企业对汽轮机超速的事故都尤为关注。2011年我厂#1、2机组由于发电机保护动作信号出现,机组ETS保护动作,在调阅SOE(事故追忆时)发现各抽汽逆止门关闭时间过长。后来通过对4台机组抽汽逆止门逻辑的整改,使抽汽逆止门关闭时间大大缩短。

关 键 词:汽轮机超速  抽汽逆止门  关闭时间  逻辑整改

The logic revision about Steam Extraction Non- Return Valve against over- speed of steam turbine
Lu Yonggang.The logic revision about Steam Extraction Non- Return Valve against over- speed of steam turbine[J].Boiler Manufacturing,2012(4):62-64.
Authors:Lu Yonggang
Affiliation:Lu Yonggang (JinShan Gangue Thermoelectric Limited company ,Fuxin 123006)
Abstract:The over-speed accident of steam turbine will seriously destroy the generating equip-ments in electric power plant, the electrical generation enterprises pay great attention to the over- speed accident of steam turbine. In 2008 the ETS protection acted when the generator protection ap-peared in No 1 and 2 generator units, we found the shut time of steam extraction non-return valve was too long in reading sequence of event system. So the logic revision was taken to steam extraction non-Return valve in 4 units to reduce the shut time significantly.
Keywords:over - speed accident of steam turbine  steam extraction non - return valve  the shuttime  the logic revision