In vitro evaluation of the cytotoxicity of two glass-ionomer root canal sealers
Authors:P Beltes  E Koulaouzidou  I Kolokuris  AH Kortsaris
Affiliation:Department of Dental Pathology and Therapeutics, Faculty of Dentistry, Aristotelion University of Thessaloniki, Greece.
Abstract:The cytotoxicity of two glass-ionomer root canal sealers (Ketac-Endo and Endion) was tested by using an established cell line, BHK21/C13. Under aseptic conditions, the sealers were prepared according to the manufacturers' directions, and 0.1 ml of each material was placed in petri dishes. After setting for 6 h, the sealers were covered with 20 x 10(4) cells per dish. The cultures were incubated at 37 degrees C for 24 h, 48 h, and 72 h. Cytotoxicity was assessed by a quantitative technique at three observation periods. Endion was highly cytotoxic, causing a significant decrease in cell density. Ketac-Endo proved to be a very biocompatible material.