首页 | 本学科首页   官方微博 | 高级检索  
     

两台UPS串联向DCS控制系统供电的设计
引用本文:郑永义,栾军.两台UPS串联向DCS控制系统供电的设计[J].仪表技术,2012(7):48-49,52.
作者姓名:郑永义  栾军
作者单位:神华乌海能源公司
摘    要:单台UPS为DCS控制系统供电,故障发生率高,电池向外部供电时间短,不能满足生产的需要,而且一旦UPS停止供电,给系统和工艺生产带来了不必要的损失。采用两台UPS串联供电连接,主/副UPS可以自动切换,延长了供电时间,减少了生产损失,给工厂带来了效益。

关 键 词:DCS  UPS  串联  供电  连接  自动切换

Design of Two Serial UPS Power Supply to the DCS Control System
ZHENG Yong-yi,LUAN Jun.Design of Two Serial UPS Power Supply to the DCS Control System[J].Instrumentation Technology,2012(7):48-49,52.
Authors:ZHENG Yong-yi  LUAN Jun
Affiliation:(Shenhua Energy Company in Wuhai,Wuhai 016040,China)
Abstract:A single UPS power supply to the DCS control system has a high failure rate and the time of battery to the external power supply is short.Thus it is unable to meet the needs of production.Once UPS stops,it would bring unnecessary losses to the system and production process.If the power supply adopts two serial UPS,the main/auxiliary UPS can automatically switch,prolong the time of power supply,reduce production loss,and bring benefits to a plant.
Keywords:DCS  UPS  series  power supply  connection  automatic switching
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号