首页 | 本学科首页   官方微博 | 高级检索  
     

城乡配电网中性点接地方式的发展及选择
引用本文:朱家骝.城乡配电网中性点接地方式的发展及选择[J].电力设备,2000(Z1).
作者姓名:朱家骝
作者单位:国家电力公司武汉高压研究所 湖北
摘    要:回顾了我国城乡配电网采用的中性点接地方式,对各种不同的中性点接地方式作了比较,并对近年来发展较快的自动跟踪补偿消弧线圈作了概要介绍。文章综合考虑了各种因素,对配电网中性点接地方式的选择提出了推荐性意见。

关 键 词:配电网  中性点接地方式  自动跟踪补偿  选择

Development and Selection of Neutral Grounding Scheme for Urban and Rural Power Networks
Zhu Jialiu.Development and Selection of Neutral Grounding Scheme for Urban and Rural Power Networks[J].Electrical Equipment,2000(Z1).
Authors:Zhu Jialiu
Abstract:Reviewing the neutral grounding schemes adopted in urban and rural power networks, the paper compares different neutral grounding schemes, and introduces briefly the automatic tracing compensation arc suppression coil, which has been developed rapidly in recent years.The paper also recommends neutral grounding schemes for distribution networks by comprehensive consideration of various issues.
Keywords:distribution network  neutral grounding scheme  automatic tracing compensation  selection  