Abstract: | Hydrogen damage in iron or 99.99% purity has been investigated by Doppler broadening measurement.Experimental results show that when the iron is charged with hydrogen in 0.5mol/L H_2SO_4 solution,the critical current density to cause hydrogen damage is 20mA/cm~2.While a little As_2O_3,saying 250mg/L,added to H_2SO_4 solution,even rather small current density.≤0.2mA/cm~2,would cause hydrogen damage.With the help ofi slow tensile test,it revealed that the hydrogen damage occurred in the specimen may be influential to the subsequent process of deformation and fracture. |