首页 | 本学科首页   官方微博 | 高级检索  
     


Persistent Scatterers Interferometry detects and measures ground subsidence in Lisbon
Authors:Sandra I.N. Heleno,Luí  s G.S. Oliveira,Maria J. Henriques
Affiliation:
  • a Instituto Superior Técnico, Instituto de Engenharia de Estruturas Território e Construção (ICIST), Av. Rovisco Pais, 1049-001 Lisboa, Portugal
  • b Laboratório Nacional de Engenharia Civil, Dep. Hidraulica e Ambiente, Av. Brasil 101, 1700-066 Lisboa, Portugal
  • c Laboratório Nacional de Engenharia Civil, Dep. Barragens de Betão, Av. Brasil 101, 1700-066 Lisboa, Portugal
  • d Altamira-Information, C/Corsega, 381, Barcelona 08037, Spain
  • e Tele-Rilevamento Europa — TRE, Via Vittoria Colonna, 7, 20149 Milano, Italy
  • Abstract:Results from the application of Persistent Scatterers Interferometry in Lisbon Metropolitan Area revealed two previously unknown subsiding urban areas: one (Laranjeiras) is located in the center of Lisbon; another (Vialonga) is to be found toward the North, in an industrial region crossed by Lisbon's main highway and railway lines. The two subsiding sectors are bordered by sharp velocity gradients, and the subsidence pattern appears partially delimited by mapped geologic faults. Surface geology and urbanization alone are unable to explain the phenomena. In the Vialonga area, the historical record of water pore pressure shows a clear decline of the levels (up to 65 m in 27 years), providing evidence of over-exploitation of groundwater resources. Limited information from wells drilled inside and outside the subsidence area points to a spatial correlation between the subsidence and the water pressure levels, and suggests that faults could be acting as hydraulic barriers in the aquifer system. The surface subsidence detected is probably caused by compaction of a clay-rich Oligocene-aged aquitard, led by over-exploitation of adjacent aquifers. The same Oligocene aquitard layer is present in the Laranjeiras area, immediately bellow a multi-layered sand-clay-limestone Miocene aquifer, but further work is needed to diagnose the possibility of over-exploitation of groundwater here. In this work we were able to independently confirm the PSI results, by comparing autonomous PSI results processed for the same geographical areas, and by comparing PSI with leveling and continuous GPS derived subsidence velocities, whose close match provided further ground validation of the space-borne PSI technique.
    Keywords:PSI interferometry   Metropolitan Lisbon   Surface subsidence   Groundwater   Leveling   GPS
    本文献已被 ScienceDirect 等数据库收录!
    设为首页 | 免责声明 | 关于勤云 | 加入收藏