首页 | 本学科首页   官方微博 | 高级检索  
     

220kV变电站10kV保护整定计算分析与探讨
引用本文:唐海军,杨承卫. 220kV变电站10kV保护整定计算分析与探讨[J]. 湖南电力, 2005, 25(1): 48-49
作者姓名:唐海军  杨承卫
作者单位:湖南常德电业局,湖南,常德,415003;湖南常德电业局,湖南,常德,415003
摘    要:以太子庙220kV变电站为例,对主变压器10kV侧限时速断、10kV出线电流速断定值整定计算中存在的一些问题进行了分析与探讨,并提出了相应的建议。

关 键 词:变电站  限时速断  电流速断  整定计算
文章编号:1008-0198(2005)01-0048-02

Analysis and discussion of 10 kV protection setting calculation in 220 kV substation
TANG Hai-jun,YANG Cheng-wei. Analysis and discussion of 10 kV protection setting calculation in 220 kV substation[J]. Hunan Electric Power, 2005, 25(1): 48-49
Authors:TANG Hai-jun  YANG Cheng-wei
Abstract:Taking the Taizimiao 220kV substation for instance, this paper analyzes and discusses some problems existing in fixed setting calculation of both main transformer 10kV side time quick-break and 10kV line current quick-break. Some suggestions are also discussed in this paper.
Keywords:220kV substation  main transformer 10kV side time quick-break  10kV line current quick-break  setting calculation  analysis and discussion  