首页 | 本学科首页   官方微博 | 高级检索  
     


Panofsky magnet for the beam extraction from the synchrotron using a fast Q-magnet and RF-knockout
Authors:S Masubuchi T Nakanishi
Affiliation:College of Industrial Technology, Nihon University, 1-2-1 Izumicho, Narashino, Chiba 275-8575, Japan
Abstract:The fast control of the beam spill extracted from a synchrotron is a key function for the spot scanning irradiation in cancer therapy application. The authors propose an extraction method which uses the quadruple field of fast response, as well as the RF-knockout. A Panofsky magnet was developed as a quadruple magnet, with a frequency response of around 10 kHz. The Panofsky magnet has a rectangular beam aperture and plate coils attached to the pole face. A model magnet has been manufactured with ferrite, and static and dynamic magnetic fields were measured. From the measurement we observed that the effects of eddy current in the plate coils were large and the uniformity of the magnetic field gradient in the beam aperture was worse than ±5% with a plate thickness of 0.02 cm and a frequency of current of 10 kHz. For the future, in a detailed design the eddy current effects have to be taken into account.
Keywords:Quadruple magnet  Synchrotron  Extraction  Cancer therapy
本文献已被 ScienceDirect 等数据库收录!