首页 | 本学科首页   官方微博 | 高级检索  
     


Biomechanical performance of cutting edge surgical needles
Authors:FH Watkins  SD London  JG Neal  JG Thacker  RF Edlich
Affiliation:Department of Plastic Surgery, University of Virginia School of Medicine, Charlottesville 22908, USA.
Abstract:The purpose of this study was to compare the biomechanical performance of cutting edge needles made of S45500 stainless steel alloy to Surgalloy stainless steel. The new high-nickel stainless steel alloy, Surgalloy, has superior performance characteristics over that of the other high-nickel stainless steel alloy, S45500. The Surgalloy needle is produced from a stronger stainless steel alloy than the S45500 needle. The Surgalloy needle has considerably greater resistance to bending than the needle produced from S45500 alloy. In addition, Surgalloy stainless steel has almost a twofold greater resistance to fracture than the S45500 stainless steel alloy.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号