首页 | 本学科首页   官方微博 | 高级检索  
     

彼阳新盖口服液中钙锌含量测定
引用本文:邱彬,吴翠敏,黄丽英. 彼阳新盖口服液中钙锌含量测定[J]. 福建分析测试, 2001, 10(3): 1454-1457
作者姓名:邱彬  吴翠敏  黄丽英
作者单位:1. 福建医科大学药学系化学教研室,福建,福州,350004
2. 福建医科大学化学综合实验室,福建,福州,350004
摘    要:本文研究了乳酸钙,葡萄糖酸锌含量测定,采用同位镀汞阳极溶出法在pH=5.8的HAc—NaAc缓冲溶液中,测定补锌制剂中锌的含量.线性范围0.02~0.08μg/ml,检出限为0.08μg/ml.以EDTA掩蔽Zn~(2+),间接KMnO_4法测定钙的含量。本文提出的方法是一种不经分离而能直接测定乳酸钙和葡萄糖酸锌的简便易行的方法.

关 键 词:同位镀汞  阳极溶出法  葡萄糖酸锌  乳酸钙  高锰酸钾法

Simutaneous hydrargyrumplate determination of zinc and calcium by stripping voltammetry
Qiu Bin,Wu Cuiming,Huang Liying. Simutaneous hydrargyrumplate determination of zinc and calcium by stripping voltammetry[J]. Fujian Anal Ysis & Testing, 2001, 10(3): 1454-1457
Authors:Qiu Bin  Wu Cuiming  Huang Liying
Abstract:In a medium of acetate buffer (pH=5.8), the potential of peak for Zn (Ⅱ) is—1.0V (vs SCE) at a glassy carbon electrcode of 0.02~0.08μg/ml was obtained, and the recovery is 98.01%~101.80%.Without separation, in the same solution, the method of KMnO_4 was used for the determination of calcium.
Keywords:Stimutaneous hydrargyrumplate  Anodic stripping  Zinc  Calcium  Determination
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号