首页 | 本学科首页   官方微博 | 高级检索  
     

半封闭压缩机电动机故障分析与排除
引用本文:林勇. 半封闭压缩机电动机故障分析与排除[J]. 建筑热能通风空调, 2005, 24(2): 71-73,83
作者姓名:林勇
作者单位:无锡商业职业技术学院电子工程系
摘    要:在中央空调系统中使用的冷水机组,普遍采用半封闭活塞式压缩机,这种压缩机的电动机直接接触制冷剂和冷冻油,并长期在一定的压力和温度下工作,电动机的工作环境比较恶劣。在机组运行维护过程中,如果使用维护不当,往往会引起电动机烧毁,使空调系统无法正常工作。而维修好的冷水机组,其电机往往容易再次烧毁。本文分析认为造成这类压缩机电动机烧毁故障的主要原因是:系统回油不良;电动机三相电流不平衡;制冷系统含水量大;缺制冷剂运转;真空运转;电源电压过低;异物进入压缩机等。要想避免维修过的压缩机电机再次很快就烧毁,必须将产生该故障的原因解决,并且在维修中不能带入新的故障因素。

关 键 词:半封闭压缩机 故障分析 中央空调系统 活塞式压缩机 冷水机组 电动机烧毁 电流不平衡 压缩机电机 直接接触 工作环境 维护过程 机组运行 烧毁故障 制冷系统 电压过低 制冷剂 冷冻油 含水量 空运转 免维修 原因
文章编号:1003-0344(2005)02-071-4

The Analysis and Solution of the Motor-trouble in Semi-hermetic Compressor
Lin Yong. The Analysis and Solution of the Motor-trouble in Semi-hermetic Compressor[J]. Building Energy & Environment, 2005, 24(2): 71-73,83
Authors:Lin Yong
Abstract:Semi-hermetic compressor often be used in the water-cooling unit of air conditioning system, and it's motor which work in rather high temperature and pressure condition, even work with refrigerator and oil, has a poor working condition. It will cause some trouble with the motor if the water-cooling unit of the air conditioning system out of operating or mending. However, the motor of water-cooling unit will be destroyed easily after mending. By studying some causing of the motor-trouble in semi-hermetic compressor, it was summarized that the main reasons include that the oil is gotback badly; the three-phase current of the motor is uneven; the water content of refrigeration is large; lack the refrigerator and operate; the vacuum operates; the power is too low in voltage; the matter enters compressor, and etc. If you want to prevent the compression-motor of maintenance from trouble soon again, you must solve the reason which produce this trouble, and can't be brought into the new trouble factor in maintenance.
Keywords:water-cooling unit   semi-hermetic compressor   motor-trouble