首页 | 本学科首页   官方微博 | 高级检索  
     

350MW超临界机组调试中存在的问题分析及处理
引用本文:刘国弼,赵峰,刘俊峰,王宏杰,陈坤. 350MW超临界机组调试中存在的问题分析及处理[J]. 河北电力技术, 2013, 0(6): 39-41
作者姓名:刘国弼  赵峰  刘俊峰  王宏杰  陈坤
作者单位:[1]西安热工研究院有限公司,西安710032 [2]中国华电富拉尔基发电厂,黑龙江齐齐哈尔161041 [3]新疆阿拉尔盛源热电厂,新疆阿拉尔843300
摘    要:对1号机组在调试过程中出现的轴承烧瓦、轴振较大、低压转子轴承金属温度偏高等问题进行分析,认为轴承自定位性能较差,汽封与转子碰磨,5号、6号轴承设计标高偏高是故障的主要原因,提出更换新瓦,控制冲转参数,降低5号、6号轴承标高等处理措施,说明处理效果,并提出相应建议。

关 键 词:超临界机组  烧瓦  轴振

Problems Analysis and Treatment During Commissioning of 350 MW Supercritical Unit
Abstract:After analysis on shaft hearing buring, large shaft vibration, high temperature of low-pressure rotor hearing metal of No.1 unit during commissioning, this paper indicates that the main causes are worse shaft self-localization per- formance, the rub of the seal and the rotor, high design level of No. 5 and No. 6 shafts, proposes the settlements, such as replacement of the new bearing, turning parameter control, lowering bearing level, explains the settlements effects, and proposes the corresponding suggestions.
Keywords:supercritical unit ~ bearing burning  shaft vibration