Assessment of the Efficacy of Intermittent Ozone Disinfection
Authors:Chang Hoon Ahn  Bruce E Rittmann
Affiliation:1. College of Engineering , Seoul National University , Seoul, Korea;2. Center for Environmental Biotechnology, Biodesign Institute, Arizona State University , Tempe, Arizona, USA
Abstract:An example of intermittent disinfection occurs in dental-unit water systems (DUWS), which are disinfected only for a specified time per each day. The efficacy of intermittent ozonation was evaluated using a laboratory-scale, membrane-based ozone disinfection system (MBODS), which delivers bubbleless dissolved ozone to the DUWS. A new tool - the weighted Ct value, or Cw, - was applied to interpret heterotrophic plate counts (HPC) data. To achieve the American Dental Association's (ADA's) criterion (<200 CFU/mL), the required ozone dosage was Cw > 0.07 mg–O3/L. However, even the highest ozone dosage (Cw > 0.130 mg/L) allowed biofilm HPC to persist at over 104 CFU/cm2. Although a higher Cw killed planktonic and biofilm bacteria more thoroughly, it also generated more biodegradable dissolved organic carbon (BDOC). Thus, this research illustrates the inherent trade-off of intermittent ozonation: a higher Cw kills more bacteria during the ozonation period, but creates more BDOC that fosters biofilm regrowth when ozonation is off.
Keywords:Ozone  Biofilm  Regrowth  Dental Unit Water Systems  Intermittent Disinfection  Weighted Ct