Spectral measurements of gamma radiation streaming through ducts |
| |
Authors: | V. Meenakshisundaram P.K. Bhatnagar V.M. Raghunath D.V. Gopinath |
| |
Affiliation: | Safety Research Laboratory, Reactor Research Centre, Kalpakkam - 603 102, India |
| |
Abstract: | The paper presents the spectral measurements of gamma radiation streaming through multi-legged rectangular concrete ducts for cesium-137 and cobalt-60 sources. Effect of lead lining the inner surface of the duct on the streaming radiation spectrum and optimization of liner thickness for minimum streaming radiation dose have been studied.For three-legged ducts, a comparative analysis of lead lining the entire duct as against lining any one or both the corners of the duct is reported. It is seen that lead lining any one of the corners would reduce the streaming radiation dose by a factor of 5 to 12. Lining both the corners which is nearly as effective as lining the entire duct reduces the dose by a factor of 16 to 60 depending on the source energy and duct dimensions. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |