黄台电厂8号机组凝结水升压泵振动分析与处理
引用本文:王福谭,栾俊,邵秀敏. 黄台电厂8号机组凝结水升压泵振动分析与处理[J]. 热力发电, 2007, 36(6): 83-86
作者姓名:王福谭  栾俊  邵秀敏
作者单位:黄台发电厂,山东,黄台,250100
摘    要:介绍了对黄台电厂8号机组乙凝结水升压泵振动的分析和处理过程。振动主要由于基础松动引起,对松动的基础重新浇灌了二次灌浆层后,泵组消振达到标准要求。

关 键 词:300 MW机组  凝结水升压泵  振动  频谱图  基础松动
文章编号:1002-3364(2007)06-0083-04

ANALYSIS AND REMEDY OF CONDENSATE- BOOSTING PUMP VIBRATION FOR UNIT NO.8 IN HUANGTAI POWER PLANT
WANG Fu-tan,LUAN Jun,SHAO Xiu-min. ANALYSIS AND REMEDY OF CONDENSATE- BOOSTING PUMP VIBRATION FOR UNIT NO.8 IN HUANGTAI POWER PLANT[J]. Thermal Power Generation, 2007, 36(6): 83-86
Authors:WANG Fu-tan  LUAN Jun  SHAO Xiu-min
Affiliation:Huangtai Poewr Plant, Huangtai 250100, Shandong Province, PRC
Abstract:The process of analysis and remedy for condensate-boosting pump vibration of unit no.8 in Huangtai Power Plant has been presented. The vibration is mainly resulted from looseness of the foundation. After re-grouting secondary grout layer on the loose foundation, the elimination of pump vibration satisfied the requirements of standard.
Keywords:300 MW unit  condensate-boosting pump  vibration  frequency spectrogram  looseness of the foundation