A case of anaphylactic shock induced by FX60 polysulfone hemodialyzer but not F6‐HPS polysulfone hemodialyzer |
| |
Authors: | Kai‐Hsiang Shu Tze‐Wah Kao Wen‐Chih Chiang Vin‐Cent Wu |
| |
Affiliation: | Division of Nephrology, Department of Internal Medicine, National Taiwan University Hospital, , Taipei, Taiwan |
| |
Abstract: | A 75‐year‐old woman was admitted for dyspnea and fever. She underwent emergent dialysis smoothly under F6‐HPS polysulfone hemodialyzer. With two subsequent hemodialysis sessions, severe anaphylactic reaction with cardiopulmonary resuscitation occurred under FX60 polysulfone dialyzer. Further dialysis sessions by F6‐HPS polysulfone dialyzer were uneventful. This rare case demonstrated that dialyzer reaction may be markedly different even with the same material and the same manufacturer. |
| |
Keywords: | Anaphylaxis hemodialysis dialyzer polysulfone |
|