首页 | 本学科首页   官方微博 | 高级检索  
     


Assessment of subjective and hemodynamic tolerance of different high‐ and low‐flux dialysis membranes in patients undergoing chronic intermittent hemodialysis: A randomized controlled trial
Authors:Giorgia Bianchi  Vanja Salvadé  Barbara Lucchini  Sibylle Schätti‐Stählin  Igor Salvadé  Michel Burnier  Luca Gabutti
Affiliation:1. Division of Internal Medicine and Nephrology, Ospedale la Carità, , Locarno, Switzerland;2. Division of Nephrology, University Hospital of Lausanne, , Lausanne, Switzerland
Abstract:Clinical experience and experimental data suggest that intradialytic hemodynamic profiles could be influenced by the characteristics of the dialysis membranes. Even within the worldwide used polysulfone family, intolerance to specific membranes was occasionally evoked. The aim of this study was to compare hemodynamically some of the commonly used polysulfone dialyzers in Switzerland. We performed an open‐label, randomized, cross‐over trial, including 25 hemodialysis patients. Four polysulfone dialyzers, A (Revaclear high‐flux, Gambro, Stockholm, Sweden), B (Helixone high‐flux, Fresenius), C (Xevonta high‐flux, BBraun, Melsungen, Germany), and D (Helixone low‐flux, Fresenius, Bad Homburg vor der Höhe, Germany), were compared. The hemodynamic profile was assessed and patients were asked to provide tolerance feedback. The mean score (±SD) subjectively assigned to dialysis quality on a 1–10 scale was A 8.4 ± 1.3, B 8.6 ± 1.3, C 8.5 ± 1.6, D 8.5 ± 1.5. Kt/V was A 1.58 ± 0.30, B 1.67 ± 0.33, C 1.62 ± 0.32, D 1.45 ± 0.31. The low‐ compared with the high‐flux membranes, correlated to higher systolic (128.1 ± 13.1 vs. 125.6 ± 12.1 mmHg, P < 0.01) and diastolic (76.8 ± 8.7 vs. 75.3 ± 9.0 mmHg; P < 0.05) pressures, higher peripheral resistance (1.44 ± 0.19 vs. 1.40 ± 0.18 s × mmHg/mL; P < 0.05) and lower cardiac output (3.76 ± 0.62 vs. 3.82 ± 0.59 L/min; P < 0.05). Hypotension events (decrease in systolic blood pressure by >20 mmHg) were 70 with A, 87 with B, 73 with C, and 75 with D (P < 0.01 B vs. A, 0.05 B vs. C and 0.07 B vs. D). The low‐flux membrane correlated to higher blood pressure levels compared with the high‐flux ones. The Helixone high‐flux membrane ensured the best efficiency. Unfortunately, the very same dialyzer correlated to a higher incidence of hypotensive episodes.
Keywords:Hemodynamics  intradialytic hypotension  dialysis membranes  high flux  low flux  hemodialysis
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号