摘    要:介绍了高频燃烧-红外吸收法测定FZNCr-60A镍基自熔合金中碳的方法。对助熔剂的种类、加入方式以及用量做了较详细的研究,同时试验了不同的样品称样量和加入顺序,确定了先加0.3g铁助熔剂,然后加0.2g试样,最后加1.5g钨锡助熔剂的最佳的加入顺序。在没有FZNCr-60A镍基自熔合金标准样品的情况下,选择含量接近的LECO501-506钢铁中碳和硫校准样品(w(C)=0.895%±0.007%)以及其他合金标样对仪器进行了校准。将实验确定的方法用于两个含量不同的实际样品中碳的测定,测得结果分别为0.857%和0.816%,相对标准偏差小于0.18%(n=11),加标回收率在99%~101%之间。

关 键 词:镍基自熔合金    高频燃烧-红外吸收法  
收稿时间:2013-11-28

Determination of carbon in nickel-matrix self-fluxing alloy by high frequency-infrared absorption method
ZHENG Li-chun;ZHANG Yong;YAN Xiu-fen;ZHANG Ji-min;YANG Li;ZHAN Xiu-yan;LI Ji-chao. Determination of carbon in nickel-matrix self-fluxing alloy by high frequency-infrared absorption method[J]. Metallurgical Analysis, 2013, 33(11): 67-70
Authors:ZHENG Li-chun  ZHANG Yong  YAN Xiu-fen  ZHANG Ji-min  YANG Li  ZHAN Xiu-yan  LI Ji-chao
Affiliation:Technique Center of AVIC Shenyang Liming Aero Engine Corporation,Shenyang 110043,China
Abstract:A method was described for the determination of carbon in nickel-matrix self-fluxing alloy by high-frequency combustion - infrared absorption. The type,adding method and dosage of the flux were studied in detail,meanwhile the dosages and adding sequence of different samples were tested,and the optimum adding sequence was determined as 0.3 g of iron,0.2 g of the sample and finally 1.5 g of tungsten-tin flux. In the absence of certified reference materials for FZNCr-60A nickel-based self-fluxing alloy,the the calibration samples( LECO 501-506) with similar content of carbon and sulfur (w(C)=0.895%±0.007%) and certified reference materials of other alloys were used to calibrate the instrument. The experimental method was used to determine the carbon content of two actual samples with different contents and the measured results were 0.857 % and 0.816 %,with the relative standard deviation less than 0.18% (n=11) and the recovery rate in the range of 99%-101%.
Keywords:nickel-based self-fluxing alloy  carbon  high frequency combustion-infrared absorption method  
本文献已被 CNKI 等数据库收录!
点击此处可从《冶金分析》浏览原始摘要信息
点击此处可从《冶金分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号