首页 | 本学科首页   官方微博 | 高级检索  
     


Monitoring and control of the biogas process based on propionate concentration using online VFA measurement.
Authors:Kanokwan Boe  Jean-Philippe Steyer  Irini Angelidaki
Affiliation:Institute of Environment & Resources DTU, Technical University of Denmark, Building 113, DK-2800, Kgs., Lyngby, Denmark.
Abstract:Simple logic control algorithms were tested for automatic control of a lab-scale CSTR manure digester. Using an online VFA monitoring system, propionate concentration in the reactor was used as parameter for control of the biogas process. The propionate concentration was kept below a threshold of 10 mM by manipulating the feed flow. Other online parameters such as pH, biogas production, total VFA, and other individual VFA were also measured to examine process performance. The experimental results showed that a simple logic control can successfully prevent the reactor from overload, but with fluctuations of the propionate level due to the nature of control approach. The fluctuation of propionate concentration could be reduced, by adding a lower feed flow limit into the control algorithm to prevent undershooting of propionate response. It was found that use of the biogas production as a main control parameter, rather than propionate can give a more stable process, since propionate was very persistent and only responded very slowly to the decrease of the feed flow which lead to high fluctuation of biogas production. Propionate, however, was still an excellent parameter to indicate process stress under gradual overload and thus recommended as an alarm in the control algorithm.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏