摘    要:采用数值模拟的方式对GIS配套用压互感器进行了研究,通过分析得到器身电场最大值为21.649kV/mm,设计裕度为3.42861kWmm,满足设计要求。试验工装电场计算的最大值为21.055kWmm,设计裕度为4.02276kV/mm,满足设计要求。

关 键 词:电压互感器  雷电冲击电压  绕组  有限元

Analysis of Supporting GIS Voltage Transformer
REN Yun-ying.Analysis of Supporting GIS Voltage Transformer[J].Shanxi Energy and Conservation,2012(6):82-83.
Authors:REN Yun-ying
Affiliation:REN Yun-ying (Pinggao Group Limited Company, Pingdingshan 467001, Henan, China)
Abstract:This paper studied using the numerical simulation method on supporting GIS voltage transformer, through analyzes the body of electric field to a maximum of 21.649 kV/mm, design margin is 3.428 61 kV/mm, meet the design requirements. The maximum value of test equipment electrie field calculation is 21.055 kV/mm, design margin is 4.022 76 kV/mm, meet the design requirements.