安全膜防爆电容器自愈性试验方法的建议 |
| |
引用本文: | 高鹏,张自魁,许峰,高儒昌. 安全膜防爆电容器自愈性试验方法的建议[J]. 电力电容器与无功补偿, 2004, 0(2) |
| |
作者姓名: | 高鹏 张自魁 许峰 高儒昌 |
| |
摘 要: | 介绍了安全膜防爆电容器目前国内外自愈性试验方法现状。又通过试验数据与分析,说明用交流电压作自愈性试验不能反映安全膜防爆电容器自愈特性的真实情况。提出用直流电压作该种电容器的自愈性试验的建议。
|
关 键 词: | 安全膜防爆电容器 自愈性试验 交流电压 直流电压 建议 |
Suggestion of Self-healing Test Methods for Safety Film Withstand Rupture Power Capacitor |
| |
Abstract: | Present status of self-healing test methods are introduced for safety film withstand rupture power capacitor at home and abroad. It is explained that self-healing test using A.C. voltage can not make ture condition of self-healing. Suggestion using D.C. voltage of this test is proposed. |
| |
Keywords: | Safety film withstand rupture power capacitor Self-healing test A.C. voltage D.C. voltage Suggestion |