首页 | 本学科首页   官方微博 | 高级检索  
     

部分竖向分布钢筋套筒挤压连接的预制剪力墙抗震性能试验研究
引用本文:李宁波 钱稼茹 刘时伟 赵作周 叶列平. 部分竖向分布钢筋套筒挤压连接的预制剪力墙抗震性能试验研究[J]. 土木工程学报, 2016, 49(7): 36-48
作者姓名:李宁波 钱稼茹 刘时伟 赵作周 叶列平
作者单位:1. 清华大学土木工程安全与耐久教育部重点实验室, 北京 100084;2. 内蒙古蒙西工程设计有限公司,内蒙古呼和浩特 010000
摘    要:为研究部分竖向分布钢筋套筒挤压连接的预制剪力墙的抗震性能,完成3个预制墙试件和1个现浇墙试件的拟静力试验,其中,2个预制墙和1个现浇墙试件的部分竖向分布钢筋套筒挤压连接,1个预制墙试件的全部竖向分布钢筋套筒挤压连接,试件的剪跨比为1.76、轴压比为0.3,试件墙端按一级剪力墙底部加强部位构造要求配置箍筋。试验结果表明:预制墙试件和现浇墙试件均以压弯破坏为主,位移角大于1/150时水平力-位移滞回曲线有一定捏拢,平均割线刚度退化规律、耗能能力基本相同,预制墙试件的弹塑性变形能力、正截面受压承载力的安全储备小于现浇墙试件,但其极限位移角大于1/70、正截面受压承载力试验值与计算值之比大于1.1。位移角不大于1/75时,3个预制墙试件的水平力-位移滞回曲线差别不大、骨架线基本一致。3个预制墙试件均达到《高层建筑混凝土结构技术规程》(JGJ 3—2010)规定的小震、中震和大震作用下结构抗震性能水准1、4、5对普通竖向构件的要求。

关 键 词:预制钢筋混凝土剪力墙   竖向钢筋套筒挤压连接   竖向分布钢筋   拟静力试验   抗震性能  

Experimental study on seismic behavior of pre-cast shear walls with partial vertical distributed steel bars pressed sleeve splicing
Li Ningbo Qian Jiaru Liu Shiwei Zhao Zuozhou Ye Lieping. Experimental study on seismic behavior of pre-cast shear walls with partial vertical distributed steel bars pressed sleeve splicing[J]. China Civil Engineering Journal, 2016, 49(7): 36-48
Authors:Li Ningbo Qian Jiaru Liu Shiwei Zhao Zuozhou Ye Lieping
Affiliation: 1. Key Laboratory of Civil Engineering Safety and Durability of the Ministry of Education, Tsinghua University, Beijing 100084, China;  2. Inner Mongolia Mengxi Engineering Design Co., Ltd., Hohhot 010000, China
Abstract:To study the seismic behavior of pre-cast shear walls with partialvertical distributed steel bars spliced by pressed sleeves, quasi-static tests wereperformed on 3 pre-cast wall specimens and 1 cast-in-situ wall specimen. Amongthem, 2 pre-cast wall specimens and the cast-in-situ wall specmen had particalvertical distributed steel bars spliced by pressed sleeves and 1 pre-cast wallspecimen had all vertical distributed steel bars spliced by pressed sleeves. Thedesigned shear span ratio and axial compressive force ratio for the specimens are1.76 and 0.3, respectively. The stirrups at the boundary elements of the wallspecimens are arranged according to the basic requirement for the strengthen areaof the grade 1 shear wall. The test results indicate that all the wall specimensfail inflexure mainly. The average secant stiffness degradation rule and energydissipation capacity are almost same, respectivelly. The lateral force-displacementhysteretic loops of all specimens with rotation angle larger than 1/150 have pinch.The elastic-plastic deformation capacity and the safety reserve of the compressivestrength of the pre-cast wall specimens are less than those of the cast-in-situwall specimen. The ultimate rotation angle is larger than 1/70 and the ratio of themeasured strength to the calculated one is larger than 1.1 for the pre-cast wallspecimens. When the rotation angle is not larger than 1/75, the lateral force-displacement hysteretic loops and skeleton curves of the 3 pre-cast wall specimensare similar. All the pre-cast wall specimens can satisfy the requirements ofordinary vertical structural elements for structural anti-earthquake performancelevel 1, 4 and 5 under the action of minimal earthquake, mediate earthquake andabnormal earthquake, respectively, according to the “technical specification forconcrete structures of tall building” JGJ 3—2010.
Keywords: