首页 | 本学科首页   官方微博 | 高级检索  
     

资源一号02D可见近红外和高光谱影像辐射质量评价
引用本文:孙培宇,柯樱海,钟若飞,赵世湖,刘瑶.资源一号02D可见近红外和高光谱影像辐射质量评价[J].遥感技术与应用,2022,37(4):938-952.
作者姓名:孙培宇  柯樱海  钟若飞  赵世湖  刘瑶
作者单位:1.城市环境过程与数字模拟国家重点实验室培育基地,北京 100048;2.水资源安全北京实验室,北京 100048;3.首都师范大学 资源环境与旅游学院,北京 100048;4.自然资源部国土卫星遥感应用中心,北京 100048
基金项目:国家自然科学基金项目(42071396);国家重点研发计划项目(2017YFC0505903)
摘    要:资源一号02D(ZY1-02D)卫星搭载了我国自主研制的可见近红外相机(VNIC)和高光谱相机(AHSI),是我国首颗民用高光谱业务卫星,具有广泛的应用前景。通过整体辐射精度、信噪比、清晰度以及信息熵4个评价指标,对ZY1-02D VNIC和AHSI数据进行辐射质量评价,并分别采用Sentinel-2 MSI和GF-5 AHSI数据进行对比。结果表明: ZY1-02D VNIC数据在可见光波段具有亮度高、信噪比高等优势;在红边近红外等波段,影像具有灰度范围大、信息量大的特点。ZY-1-02D VNIC数据在影像亮度、灰度范围、清晰度和信息量方面均优于Sentinel-2,二者信噪比近似。ZY-1-02D AHSI数据在395—1 341 nm范围内辐射质量良好;在1 929—2 501 nm范围,存在噪声严重的波段,影像质量较差。与GF-5 AHSI数据对比,ZY-1-02D AHSI数据的影像亮度和信噪比相当,但ZY-1-02D AHSI数据在灰度范围方面优势明显,且短波红外谱段的清晰度和信息量优于GF-5 AHSI数据。

关 键 词:资源一号02D卫星  影像质量评价  Sentinel-2  GF-5  高光谱数据  
收稿时间:2021-07-26

Radiance Quality Assessment of ZY-1-02D VNIC/AHSI Image Data
Peiyu Sun,Yinghai Ke,Ruofei Zhong,Shihu Zhao,Yao Liu.Radiance Quality Assessment of ZY-1-02D VNIC/AHSI Image Data[J].Remote Sensing Technology and Application,2022,37(4):938-952.
Authors:Peiyu Sun  Yinghai Ke  Ruofei Zhong  Shihu Zhao  Yao Liu
Abstract:ZY-1-02D is the first civil hyperspectral satellite in China, equipped with Visible Near-Infrared Camera (VNIC) and Advanced Hyperspectral Imager (AHSI). This study evaluates and analyzes the radiance quality of ZY-1-02D VNIC/AHSI data and compares them with Sentinel-2 MSI/GF-5 AHSI data. Four indicators are used to assess image quality: radiance precision, Signal-to-Noise Ratio (SNR), definition, and Shannon entropy. The results indicate that ZY-1-02D VNIC data has the advantages of high radiance and high SNR in visible bands. In red-edge and near-infrared bands, ZY-1-02D VNIC data has the advantages of a large gray range and a large amount of information. The comparison between ZY-1-02D and Sentinel-2 MSI data shows that ZY-1-02D VNIC data has better performance in radiance, gray range, definition, and information content. The performance of the two sensors is similar in terms of SNR. ZY-1-02D AHSI data has great quality in 395~1 314 nm wavelength. However, in 1 929—2 501 nm, some bands have severe noise and poor quality caused by water vapor. The comparison between ZY-1-02D AHSI and GF-5 AHSI data shows that the performance in radiance and SNR of the two sensors are similar. The gray range of ZY-1-02D AHSI data is greater than GF-5 AHSI data in both VNIR and SWIR. The definition and information content of ZY-1-02D AHSI data are better than GF-5 AHSI data in SWIR bands.
Keywords:ZY-1-02D  Image quality assessment  Sentinel-2  GF-5  Hyperspectral data  
点击此处可从《遥感技术与应用》浏览原始摘要信息
点击此处可从《遥感技术与应用》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号