宝钢3号高炉冷却壁破损的原因及防止对策
引用本文:曹传根,周渝生,叶正才. 宝钢3号高炉冷却壁破损的原因及防止对策[J]. 炼铁, 2000, 19(2): 1-5
作者姓名:曹传根  周渝生  叶正才
作者单位:宝山钢铁集团公司
摘    要:宝钢3号高炉冷却壁破损的主要原因是耐火材料选择不合理,冷却壁设计不合理,冷却水质控制不好,渣皮不稳定等.通过采取在冷却壁本体上安装微型冷却器、加强高炉操作管理和水质管理等措施,有效地抑制了冷却壁损坏.

关 键 词:高炉 冷却壁 微型冷却器 耐火材料 水质管理
修稿时间:1999-12-06

The cause and preventing measure of stave destruction of No. 3 BF in Baosteel
Cao Chuan''''gen Zhou Yusheng Ye Zhengcai. The cause and preventing measure of stave destruction of No. 3 BF in Baosteel[J]. Ironmaking, 2000, 19(2): 1-5
Authors:Cao Chuan''''gen Zhou Yusheng Ye Zhengcai
Abstract:The main causes of stave destruction at Baosteel No.3 BF are as follows:unreasonable refractory selection and stave design,bad quality cooling water, etc. . A series of measures are adopted on Baosteel No. 3 BF, such as installing cigar-cooler in stave body, strengthing the management of BF operation and water quality.The destruction of stave is effectively controlled.
Keywords:blast furnace stave cigar-cooler  