摘    要:针对高压直流输电系统受端三相接地故障线路切除后的换相失败问题,从机理角度阐述切除大容量机组近区三相接地故障线路后的机组功角振荡过程及功角振荡特性,分析振荡中心近区电压变化特征、振荡中心近区换流站换相失败的风险并推广至线路任意直流落点,总结定熄弧角控制降低振荡中心近区换流站换相失败风险的关键影响因素.仿真结果表明理论分析...

关 键 词:高压直流输电  换相失败  功角振荡  振荡中心  定熄弧角控制

Analysis and Simulation of Commutation Failure near Oscillation Center in Power System
LIU Zengxun,ZHANG Shang,WANG Weiyuan,CHENG Baohua.Analysis and Simulation of Commutation Failure near Oscillation Center in Power System[J].Proceedings of the CSU-EPSA,2022,34(2):39-47.
Authors:LIU Zengxun  ZHANG Shang  WANG Weiyuan  CHENG Baohua
Affiliation:(State Grid Corporation of China,Beijing 100031,China;State Key Laboratory of Power Grid Safety and Energy Conservation,China Electric Power Research Institute,Beijing 100192,China;State Grid Jiangsu Electric Power Co.,Ltd,Nanjing 211106,China;School of Control and Mechanical Engineering,Tianjin Chengjian University,Tianjin 300384,China)
Abstract:Aimed at the commutation failure problem in a HVDC transmission system at its receiving end after a line un?der three-phase grounding fault is cut off,the power-angle oscillation process of the unit and the corresponding oscilla?tion characteristics after cutting off the line near the large capacity unit are expounded from the perspective of mecha?nism analysis.The voltage variation characteristics near the oscillation center are analyzed,and the risk of commutation failure of a converter station near the oscillation center is discussed,which is further extended to any DC drop point on the line.In addition,the key influencing factors for reducing the risk of commutation failure by the constant extinction angle control are summarized.Simulation results verify the theoretical analysis performed in this paper.
Keywords:HVDC transmission  commutation failure  power-angle oscillation  oscillation center  constant extinction angle control