首页 | 本学科首页   官方微博 | 高级检索  
     


A comparison of gas velocity measurements in a full-scale enclosure fire
Authors:Rodney A. Bryant
Affiliation:Building and Fire Research Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
Abstract:Gas velocity measurements were conducted in the doorway of an enclosure containing a natural gas fire. Two independent measurement techniques, Stereoscopic Particle Image Velocimetry (SPIV) and bi-directional impact-pressure probes, were utilized for comparison – the first such comparison for a fire-induced flow in a full-scale structural fire. Gas velocities inferred from the bi-directional probe measurements were consistently greater than SPIV measurements in a region of the flow between the floor and the flow interface. The comparison revealed that a measurement bias exists in the bi-directional probe technique. Estimates of the relative magnitude of the bias were inferred from the results.
Keywords:Flow measurement   Fire-induced flow   Particle image velocimetry   Bi-directional probe
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号