摘    要:根据对现有医疗废水检测方式的不足,设计了一种自动检测系统。该系统通过检测透射光的强度确定样品溶液中含余氯的浓度,具有自动取样、自动清洗、干燥、排放、连续精密检测等功能。该系统的测试结果与常规余氯的测试结果基本一致。

关 键 词:医疗污水  余氯  自动检测  模数转换器  光缆
文章编号:1000-9787(2005)05-0049-03
修稿时间:2004-11-28

Automatic system of examining residual chlorine in medical wastewater
WANG Hao,GUAN Yi. Automatic system of examining residual chlorine in medical wastewater[J]. Transducer and Microsystem Technology, 2005, 24(5): 49-51
Authors:WANG Hao  GUAN Yi
Abstract:According to the shortage of examining method for medical wastewater at present,an automatic examining system is designed.Through testing the intensity of the transmitted light to determine the concentration of chlorine in the solution,the automatic system can take sample,wash pipe,make try automatically and test continuously and accurately.The testing result of the system is consistent with that of the normal residual chlorine examining method basically.