首页 | 本学科首页   官方微博 | 高级检索  
     

娘子关电厂410t/h锅炉燃烧调整试验研究
引用本文:贾国璋 李东雄. 娘子关电厂410t/h锅炉燃烧调整试验研究[J]. 电力学报, 2000, 15(3): 215-217,219
作者姓名:贾国璋 李东雄
作者单位:[1]娘子关发电厂 [2]太原电力高等专科学校
摘    要:分析了娘子关电厂 3#炉大修后试运行过程中发生炉内结渣的原因 ,介绍了通过燃烧调整解决炉内结渣和低负荷不投油稳燃的经验 ,对同类型锅炉的燃烧调整有借鉴作用

关 键 词:锅炉  结渣  燃烧调整

Study on Combustion Regulation of 410 t/h Boiler
Jia Guozhang. Study on Combustion Regulation of 410 t/h Boiler[J]. Journal of Electric Power, 2000, 15(3): 215-217,219
Authors:Jia Guozhang
Affiliation:Jia Guozhang(Niangziguan Power Plant) Li Dongxiong(Taiyuan Higher Electrical College) Xu Shiwen(Niangziguan Power Plant)Hao Rui(Shanxi Electrical Scientific Research Institute)
Abstract:The cause of furnace slagging of No.3 of Niangziguan Power Plant during its priliminary operation after major repair is analyzed.The successful experience to prevent furance slagging and make the boiler operate with stable combustion without supporting oil at low load through burning regulation is introduced.it may be provided as a reference for burning regulation of the same type boiler.
Keywords:boiler  furnace slagging  burning regulation
本文献已被 CNKI 维普 等数据库收录!