摘    要:为降低空预器漏风率,从结构设计分折得出空、烟气压差大和密封间隙大是其漏风的主要原因,通过采取高压水冲洗,气脉冲燃气吹灰,双密封改造,空预器重新选型等一系列措施来降低漏风率。

关 键 词:妈湾电厂 锅炉 空气预热器 漏风率 风机 引风机
文章编号:1006-348X(2003)02-32-04

Measures of Reduced Air leakage Rate of the Air Preheater in Mawan Power Plant
CHENG XIN-pin. Measures of Reduced Air leakage Rate of the Air Preheater in Mawan Power Plant[J]. Jiangxi Electric Power, 2003, 27(2): 32-35
Authors:CHENG XIN-pin
Affiliation:CHENG XIN-pin
Abstract:Frome construstion design of air preheater analyzed that the main cause of air leakage is flue gas heavy pressure difference and big sealing clearance. Through using a series of measures of high-pressure watering pulse gas sootblowing double sealing improving?air preheater re-select type reduced air leakage rate.
Keywords:thermal power plant  air preheater  air leakage rate  air pulse gas sootblowing  double sealing improvement  air leakage control system   high-pressure watering