摘    要:电弧炉是一种严重的不对称冲击负载,它将产生大量的负序分量而污染电网,所以需要对其进行平衡化补偿。本文推导了平衡化补偿的实用公式,并利用动模实验进行了验证。

关 键 词:电弧炉  平衡化补偿  无功补偿  晶闸管控制电抗器(TCR)
修稿时间:2000-10-18

Deriving and Verifying a Practical Formula of Balancing Compensation for Arc Furnace
Li Peng,Shi Xinchun,Liang Zhirui,Chen Zhiye. Deriving and Verifying a Practical Formula of Balancing Compensation for Arc Furnace[J]. Transactions of China Electrotechnical Society, 2001, 16(1): 77-80
Authors:Li Peng  Shi Xinchun  Liang Zhirui  Chen Zhiye
Abstract:Arc furnace is a typical unbalanced impact load.It po urs a great deal of negative sequence component to power system,so measures shou ld be taken to compensate the arc furnace load.A practical formula for balancing compensation is presented.The formula has been verified by physical-simulation experiments.