首页 | 本学科首页   官方微博 | 高级检索  
     

基于改进主动轮廓模型的心室内窥显示及测量
引用本文:曾理,郭海燕,侯立华,HUNZIKER P.R.. 基于改进主动轮廓模型的心室内窥显示及测量[J]. 计算机工程与应用, 2007, 43(19): 210-213
作者姓名:曾理  郭海燕  侯立华  HUNZIKER P.R.
作者单位:重庆大学,光电技术及系统教育部重点实验室,ICT研究中心,重庆,400030;重庆大学,数理学院,重庆,400030;重庆大学,数理学院,重庆,400030;河南商业高等专科学校,基础部,郑州,450045;瑞士巴塞尔大学,医学院,瑞士,CH4031
基金项目:国家自然科学基金 , 重庆市科技计划 , 重庆大学校科研和教改项目
摘    要:将改进的Snake模型应用于心脏超声波图像处理:基于改进Snake模型的思想,得到了心脏超声波图像二维切片序列的轮廓点,在此基础上,得到分割出的心室上下左右4个曲面上轮廓点到中心平面的距离矩阵,并通过插值和平滑处理以及滤波处理工作,拟合出心室的三维曲面图(内窥曲面),取得了较好的效果;在医学测量方面,对心室的切片面积、变化趋势及心室的体积进行了测量。实验表明,Snake模型应用于心脏超声波图像处理中是可行的,在三维医学图像处理中有较大的应用前景。

关 键 词:主动轮廓模型  计算机图像处理  心脏超声波图像  轮廓提取  三维显示  容积测量
文章编号:1002-8331(2007)19-0210-04
修稿时间:2006-11-01

Endoscopic image show and measure of ventricle based on improved active contour model
ZENG Li,GUO Hai-yan,HOU Li-hua,HUNZIKER P.R.. Endoscopic image show and measure of ventricle based on improved active contour model[J]. Computer Engineering and Applications, 2007, 43(19): 210-213
Authors:ZENG Li  GUO Hai-yan  HOU Li-hua  HUNZIKER P.R.
Affiliation:1.ICT Research Center,Key Laboratory of Optoelectronic Technology and System of the Education Ministry of China,Chongqing University,Chongqing 400030,China 2.College of Mathematics and Physics,Chongqing University,Chongqing 400030,China 3.Basic Department,Henan Business College,Zhengzhou 450045,China 4.University Hospital of Basel,Basel,CH 4031,Switzerland
Abstract:In this paper,the updated Snake model is used to solve the echocardiography processing.Based on the updated active contour model,the contour points for two-dimensional slice serial of echocardiography are gotten.On this basis,through calculating the distance between the contour points of each two-dimensional slice and the center axis lines,the distance matrix from the four cambers of the ventricle to the center plane of ventricle are gotten.And through interpolating,smooth handling and filtering,the 3D endoscopic surface of ventricle is fitted out.Besides,in the medical measurements field,the slice area of ventricle and the volume of ventricle are measured,and the trend of slice area is also analyzed.The experiment shows that it’s feasible to use the algorithm of the active contour model for echocardiography processing.Moreover,it has biggish foreground in 3-D image processing of medical field.
Keywords:active contour model   computer image processing   echocardiography   contour pick-up   3-D display   volume measurement
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《计算机工程与应用》浏览原始摘要信息
点击此处可从《计算机工程与应用》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号