首页 | 本学科首页   官方微博 | 高级检索  
     

高比转速轴流泵叶轮与导叶的正交试验优化
引用本文:赵勇,董威,肖业祥,汪程鹏,王东,王生辉. 高比转速轴流泵叶轮与导叶的正交试验优化[J]. 水力发电学报, 2022, 41(3): 92-100. DOI: 10.11660/slfdxb.20220309
作者姓名:赵勇  董威  肖业祥  汪程鹏  王东  王生辉
作者单位:长安大学 道路施工技术与装备教育部重点实验室,西安 710064;清华大学 水沙科学与水利水电工程国家重点实验室 & 能源与动力工程系,北京 100084;自然资源部 天津海水淡化与综合利用研究所,天津 300192;自然资源部 天津海水淡化与综合利用研究所,天津 300192;海南大学 机电工程学院,海口 570228
基金项目:海南省重点研发计划;大学生创新创业训练项目;国家重点实验室开放基金
摘    要:高比转速轴流泵广泛应用在防洪排涝等特殊场合,但其水力效率普遍偏低.为提高其水力效率,并达到节能效果,本文对比转速为1400轴流泵的叶轮与导叶采用正交试验进行水力优化,并探究优化前后泵的内流特性.先对轴流泵叶轮和导叶的几何形状进行参数化解析,对参数化后的控制尺寸设置控制因素,以水力效率为指标设计正交试验,并对正交试验结果...

关 键 词:轴流泵  叶轮  导叶  水力效率  正交试验

Orthogonal test optimization of impeller and diffuser of high specific speed axial flow pumps
ZHAO Yong,DONG Wei,XIAO Yexiang,WANG Chengpeng,WANG Dong,WANG Shenghui. Orthogonal test optimization of impeller and diffuser of high specific speed axial flow pumps[J]. Journal of Hydroelectric Engineering, 2022, 41(3): 92-100. DOI: 10.11660/slfdxb.20220309
Authors:ZHAO Yong  DONG Wei  XIAO Yexiang  WANG Chengpeng  WANG Dong  WANG Shenghui
Abstract:The axial flow pump of high specific speed is widely used for flood control, waterlog drainage, and other special occasions, but its hydraulic efficiency is generally low. To achieve energy-saving effects and a higher efficiency, this paper adopts orthogonal tests to optimize the impeller and diffuser of a 1400 axial flow pump, and examines the internal flow behaviors of the pump and its optimized version. First, a geometric parameter analysis is made for the impeller and diffuser, and control factors are imposed on the parameterized control dimensions. Then, we design a set of orthogonal tests using hydraulic efficiency as the objective index, and conduct a range analysis of the test results so as to determine the key factors in the pump’s hydraulic performance. Thus, orthogonal test optimization of the impeller and guide vanes is achieved for different levels of the key factors via adjusting the geometric parameters of the blade airfoil. We found that flow separation and backflow vortices in the impeller and diffuser sections optimized by cross-test are suppressed effectively, and the pressure concentration area on impeller surface is expanded, resulting in a greater driving force and a significant reduction in the hydraulic losses in the sections of impeller, diffuser and outlet pipe. And an improvement on the pump’s hydraulic efficiency by 13.2% has been achieved in and the pump head is increased to the design level of 6.3 m.
Keywords:axial flow pump  impeller  diffuser  hydraulic efficiency  orthogonal test  
本文献已被 万方数据 等数据库收录!
点击此处可从《水力发电学报》浏览原始摘要信息
点击此处可从《水力发电学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号