首页 | 本学科首页   官方微博 | 高级检索  
     

华龙一号小幅功率提升研究
引用本文:向美琼,朱加良,刘艳阳,青先国,何正熙,吴 茜,朱毖微,吕 鑫.华龙一号小幅功率提升研究[J].核动力工程,2021,42(3):115-122.
作者姓名:向美琼  朱加良  刘艳阳  青先国  何正熙  吴 茜  朱毖微  吕 鑫
摘    要:对华龙一号热功率精度进行了分析,计算了蒸汽发生器出口压力测量精度、给水温度测量精度和给水流量测量精度对华龙一号热功率精度的贡献度,通过定量化的数据证明了主给水流量测量精度对热功率计算精度的影响最大。基于目前孔板流量计精度低,长期使用精度劣化的问题,提出采用高精度(0.3%)的超声波流量计来测量主给水流量,计算结果表明,采用超声波流量计可以获得0.97%的功率提升。 

关 键 词:华龙一号    热功率精度    小幅功率提升    主给水流量    超声波流量计

Study on Small Power Improving of HPR1000
Abstract:The thermal power accuracy of HPR1000 was analyzed, and the contribution of steam generator outlet pressure measurement accuracy, feed water temperature measurement accuracy and feed water flow measurement accuracy to HPR1000 thermal power accuracy was calculated. The quantitative data proves that the main feedwater flow measurement accuracy has the greatest influence on the thermal power calculation accuracy. Considering the current problem of low accuracy and the deterioration of the orifice flowmeter due to long-term use, a high-precision (0.3%) ultrasonic flowmeter is proposed to measure the main feed water flow. The calculation shows that the ultrasonic flowmeter can achieve a power increase of 0.97%. 
Keywords:
本文献已被 CNKI 等数据库收录!
点击此处可从《核动力工程》浏览原始摘要信息
点击此处可从《核动力工程》下载全文