首页 | 本学科首页   官方微博 | 高级检索  
     

哈锅670t/h炉正交法效率试验及结果分析
引用本文:金华.哈锅670t/h炉正交法效率试验及结果分析[J].吉林电力,1995(1).
作者姓名:金华
作者单位:吉林热电厂
摘    要:介绍了吉林热电厂对15号炉用正交法作热效率试验的情况。正交法采用4个因素,3个水平,进行9次试验,得出了热效率最佳的操作方式。结合试验结果还分析了该炉在经济运行中存在的问题,提出了改进措施。

关 键 词:热效率试验  正交法  排烟温度

Thermal Efficiency Test of Harbin 670t/h Boiler by Orthgonal Method and its Result Analysis
Jin Hua.Thermal Efficiency Test of Harbin 670t/h Boiler by Orthgonal Method and its Result Analysis[J].Jilin Electric Power,1995(1).
Authors:Jin Hua
Abstract:The status of applying orthogonal method to the No. 15 boiler thermal efficiency test in jilin Heat and Power Plant is recommended. In this method, 4 factors and 3 levels were adopted; through 9 times of test the operating mode of optimum efficiency was got. Combining with the test results, the existing problems in economical operation were analyzed and the improving measures were also presented.
Keywords:Thermal efficiency test Orthogonal method Exit gas temperature  
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号